ASCB1-M Smart Circuit Breaker Gateway

Multifunctional circuit breaker

 

 

2dfc833a7783519a0321a0e8da7b7645.jpg
               

 


 

Main Feature

● Over Current / Power / Temp. Protection;

● Over / Under Voltage Protection;

● Short Circuit Protection;

● Leakage Current Protection.

 


 

Appearance

 

   

 

ASCB1-M
Length
Width
Height
Parameter(mm)
109
36
75.5

 

 

 

 


 

Parameter

Product Model
ASCB1-M-4G
ASCB1-M-CE
Power Supply
AC 220V
Consumption
≤30W
Communication
4G
Ethernet
Display
LCD dot-matrix
Incident Record
Up to 20 alarm, fault and action records each
Protocol
Modbus、MQTT and so on
Elevation Requirements
2000m
Ambient Temperature
-10℃-55℃,24h the average temperature is not higher than 40℃
Environmental Requirements
No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
Relative Humidity
At + 40℃, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
Storage Temperature
-20℃-70℃
Levels of Protection
IP20
Way to Installation
 Standard 35mm guide rail installation

 

 

Function
 
ASCB1 Smart Gateway Function
 
 
 
ASCB1-M-CE
· Can connect to up to 16 intelligent micro circuit breakers
· See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
· You can view the fault, alarm and separation status of each intelligent micro circuit breaker
· It can set and control the parameters for each intelligent micro circuit breaker
· Din rail type installation, LCD LCD display
· Support event logging; support RS485 communication
· Support for Ethernet communication.
 
 
 
ASCB1-M-4G
· It can connect to up to 16 smart micro circuit breakers
· Can see the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
· Can view the fault, alarm and separation status of each intelligent micro circuit breaker
· It can set and control the parameters for each intelligent micro circuit breaker
· Din rail type installation; LCD LCD display
· Support event logging; support RS485 communication
· Support for 4G network communication
 

 

Wiring
 

Step1: Connect the RS485 port on the gateway to the BUS port of the circuit breaker by using the communication cable provided by the gateway Step2: Insert the barbed side of the connecting wire of the circuit breaker into the external terminal of the previous circuit breaker toward the outside of the terminal, and the colors need to be matched one by one.


 

 
 

 

Typical Connection

 

 

 

 


 


 

FAQ

 


Q: Can the circuit breaker data be collected through RS485 communication?

 

A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

 

 

 

Q: How many circuit breakers can a gateway carry?

 

A: 16PCS

 

Q: How Gateways and Circuit Breakers are Networked?

 

A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
The connection between the circuit breaker and the circuit breaker is the same.
One-key addressing operation through the gateway

 

Q: Does the circuit breaker need to be equipped with additional accessories?

 

A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
3. Configure the circuit breaker network cable


Hot Products

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

AMC300L Base Station AC Multi-loop Intelligent Power Collection and Monitoring Device

6 channel 3 phase or 18 channel 1 phase

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

With Different Size of CTs,easy to install D10,D16,D24,D36

Acrel ADW600 Multi Channels Smart 3 Phase Energy Meter

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

AM6 Prefabricated Substation Protection & Control Device

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

ATU Intelligent Monitoring Terminal for Switchgear

Conduct centralized monitoring and management.

Inquiry

If you have any suggestions or question for us.Please contact us
*Name
Tel
*E-mail
Address
*Message