Hot Products
The ADW600 multi circuit power metering module is mainly used to measure three-phase active energy in low-voltage networks, and has the advantages of small size, easy installation, and rich functions. The product adopts a modular design, including voltage module, current module, switch module, temperature measurement and leakage module, etc. The modules are connected by Ethernet cables and can support multi circuit splicing. Suitable for low-voltage side multi circuit metering scenarios, especially for power transformation needs.
Main Feature
● Full electric parameter measurement,Multi Channels independent metering
● With Different Size of CTs,easy to install D10,D16,D24,D36
● RS485 standard, Optional 4G Ethernet or WIFI
● Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring
● Application: for the Multi channels places
Parameter
|
ADW600-U |
Rated voltage |
3×57.7/100V, 3×220/380V, 3×100V, 3×380V |
|
Voltage accuracy |
0.5% |
|
|
Reference frequency |
45-65 Hz |
|
|
Power consumption |
<0.5VA per phase |
|
|
ADW600-I |
Input Current |
D10:0.03-0.15(6)A, D16:0.8-2(100)A, D24:3.2-8(400)A, D36: 4.8-12(600)A |
|
Active energy accuracy |
Class B |
|
|
Energy pulse width |
80±20ms |
|
|
Active pulse constant |
D10: 6400 imp/kWh , D16: 400 imp/kWh , D24: 100 imp/kWh , D36: 60 imp/kWh |
|
|
Power consumption |
<1VA per phase |
|
|
ADW600-K |
Switch input |
4-way passive input, built-in DC12V power supply |
|
Switching output |
2-way passive output, capacity AC230V/DC30V, 3A |
|
|
ADW600-TL |
Temperature measurement |
12-channel temperature measurement, accuracy ±2°C, 12 temperature measurement lines as standard |
|
Residual current measurement |
4-way residual current measurement, input maximum 1mA, accuracy 1%, residual current transformer needs to be purchased separately |
|
Temperature range |
Operating temperature |
-25 ℃ ~ 55 ℃ |
|
Storage temperature |
-40 ℃ ~ 70 ℃ |
|
|
humidity |
≤95% (no condensation) |
|
|
altitude |
<2000m |
|
Dimension
Wiring
Hot Products

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.
Inquiry