Hot Products
AM6-PWC integrates protection, control, measurement, communication and networking for prefabricated substations. Designed for photovoltaic, energy storage and wind power step-up substations, it supports rich I/O, IEC 60870-5-103/Modbus communication, event records and fault waveform recording.
Main Feature
• Independent operating circuit, adaptive to 0.25–5 A circuit-breaker tripping and closing current.
• 8 AC current channels and 7 AC voltage channels for HV-side and LV-side voltage/current acquisition.
• 43 active digital inputs and 10 independently configurable dry-contact outputs.
• 2 × 4–20 mA DC measurement channels and 3 temperature measurement channels.
• USB upgrade plus export of settings, event records and fault waveform records.
• 2 × 4–20 mA analog transmitter outputs, configurable through programmable logic software.
• Protocol conversion with 8 RS485 ports for inverter and auxiliary-device data acquisition.
• Fibre-optic ring network support, 3 Ethernet ports and 2 optical-module slots.
Technical Specification
| Power supply | AC/DC 110 V or AC/DC 220 V; operating range ±20%; power consumption ≤20 VA |
| Voltage input | HV side AC 100 V line voltage or 100/√3 V phase voltage; LV side AC 800 V. Measuring range: HV 0.1–120 V, LV 0.1–1000 V. Accuracy: Class 1 |
| Current input | AC 1 A or 5 A. Measuring range: 0.04 In–20 In. Accuracy: Class 0.5 |
| Frequency | 50/60 Hz rated; 40–70 Hz range; accuracy ±0.005 Hz |
| Digital input | AC/DC 110 V or 220 V; pickup threshold 70% Un; return threshold 55% Un |
| Digital output | mechanical life ≥10,000 operations; making capacity ≥1000 W; continuous current ≥5 A; short-time current ≥30 A/200 ms; breaking capacity ≥30 W |
Dimension

Wiring
Application
Hot Products

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.

6 channel 3 phase or 18 channel 1 phase

With Different Size of CTs,easy to install D10,D16,D24,D36

Optional 4DI2DO,12 channels temp measure,4 channels Residual current monitoring

2 × 4–20 mA DC measurement channels and 3 temperature measurement channels

Conduct centralized monitoring and management.
Inquiry